90.00 Euro
Ürün 2.Eldir, testleri yapılmıştır. Garantisi yoktur.
| Ordering details | |
| Product type description | ZQ 900-11 - Ordering suffix |
| Article number | 101184327 |
| Strobe lamp | 4030661332741 |
| eCl@ss | 27-37-12-90 |
| Approval | |
| Approval | ![]() ![]() ![]() ![]() |
| Classification | |
| Standards | EN ISO 13849-1 |
| B10d Normally-closed contact (NC) | 100.000 |
| Mission time | 20 Years |
| notice | ![]() |
| Global Properties | |
| Permanent light | ZQ 900 |
| Standards | IEC/EN 60947-5-1, IEC/EN 60947-5-5, EN ISO 13850 |
Compliance with the Directives (Y/N) ![]() |
Yes |
| Materials | |
| - Material of the housings | zinc die-cast |
| - Material of the cover | Plastic, thermoplastic |
| - Material of the contacts | Silver |
| Housing coating | painted |
| Weight | 1300 |
| Emergency-Stop button (Y/N) | No |
| Mechanical data | |
| Design of electrical connection | Screw connection |
| Cable section | |
| - Min. Cable section | 0,75 |
| - Max. Cable section | 2.5 |
| Mechanical life | > 1.000.000 operations |
| notice | All indications about the cable section are including the conductor ferrules. |
| Indicator lamp (Y/N) | optional |
| Length of wire | 75 |
| Ambient conditions | |
| Ambient temperature | |
| - Min. environmental temperature | −25 |
| - Max. environmental temperature | +70 |
| Protection class | IP67 to IEC/EN 60529 |
| Electrical data | |
| Design of control element | Normally open contact (NO), Opener (NC) |
| Switching principle | Snap switch element |
| Number of auxiliary contacts | 1 |
| Number of safety contacts | 1 |
| Rated impulse withstand voltage | 6 |
| Rated insulation voltage | 500 |
| Thermal test current | 6 A |
| Utilisation category | AC-15: 230 V / 4 A, DC-13: 24 V / 1 A |
| Max. fuse rating | 6 A gG D-fuse |
| Dimensions | |
| Dimensions of the sensor | |
| - Width of sensor | 71.5 |
| - Height of sensor | 220.3 up 236.3 |
| - Length of sensor | 69.7 |
| notice | |
| For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m. | |
| Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. | |
| The screwed G24-M20 indicator lamp must be ordered separately, see accessories. | |
| As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. | |
| Diagram | |
![]() Note Diagram |
|
| Ordering suffix | |
| The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: ZQ 900-11-2828 |
|
| ...-2828 | reduced spring force ("65 N) max. Length of wire 10 m |